  • D.S. Hier, J. Butler and R. Lewis, "Hole's Human Anatomy and Physiology". 9th ed., McGraw-Hill, New York, (2002), pp. 824, 842-843. J. Guo, M. Chen, H. Fa, X. Luo and Y. Ma, Sens. Actuators B 238 (2017) 1316. C.A. Burtis and E.R. Ashwood, "Titz Textbook of Clinical Chemistry". 3rd ed., W.B. Saunders Company, Philadelphia, (1999), pp. 1241-1242, 1245-1249. H.W. Yu, J.H. Jiang, Z. Zhang, G.C. Wan, Z.Y. Liu, D. Chang and H.Z. Pan, Anal. Biochem. 519 (2017) 92. P. Zuman, In "Polarography of biomolecules. Experimentals Methods in Biophysical Chemistry". (C. Nicotan, Ed.), Wiley, New York, (1973), pp. 393-414. Y. Wang, Y. Huang, B. Wang, T. Fang, J. Chen and C. Liang, J. Electroanal. Chem. 782 (2016) 76. Z. Bai, C. Zhou, H. Xu, G. Wang, H. Pang and H. Ma, Sens. Actuators B 243 (2017) 361. S.P.Kounaves, Voltammetric techniques, (Ch. 37), (2001), from: http://www. Yahoo.com/science,chemistry,electrochemistry, ch.37. htm. p. 709-725, yahoo.inc., Accessed: Sept., 15, 2003. Q. Qin, X. Bai, and Z. Hua, J. Electroanal. Chem. 782 (2016) 50. 74. Q. Zhu, J. Bao, D. Huo, M. Yang, C. Hou, H.H. Willard, L.L. Merritt and J.A. Dean, "Instrumental Methods of Analysis". 5th ed., D. Van Nostrand Company, New York, (1974), pp. 633, 637-638, 642-643, 655-656.

Clinical Applications of Uric Acid via Chemical Method using Polarography Technique Comparing with Spectrophotometric Methods

Year 2018, Issue: 4, 156 - 161, 04.12.2018

Abstract

Uric
acid is considered one of the important biological compounds in the human body
and one of the vital indicators for the medical diagnosis of many diseases,
kidney diseases and others. The  study
includes determination of uric acid in urine by polarography  technique and comparing the results with
those obtained by the routine spectrophotometric technique , the estimation of
the products from using Folin-Denis reagent as indicator to detect uric acid in
patients with renal, renal failure and hypertention comparing with normal these
disease cause obvious decrease in uric acid concentration in patients urine.Determination
of uric acid by chemical method using polarogrphyic  technique (DPP), it showed an obveous
reduction current peak at potential (- 0.6155 V) .DPP technique gave better
result comparing with spectrophotometric method in effort, time and cost.

References

  • D.S. Hier, J. Butler and R. Lewis, "Hole's Human Anatomy and Physiology". 9th ed., McGraw-Hill, New York, (2002), pp. 824, 842-843. J. Guo, M. Chen, H. Fa, X. Luo and Y. Ma, Sens. Actuators B 238 (2017) 1316. C.A. Burtis and E.R. Ashwood, "Titz Textbook of Clinical Chemistry". 3rd ed., W.B. Saunders Company, Philadelphia, (1999), pp. 1241-1242, 1245-1249. H.W. Yu, J.H. Jiang, Z. Zhang, G.C. Wan, Z.Y. Liu, D. Chang and H.Z. Pan, Anal. Biochem. 519 (2017) 92. P. Zuman, In "Polarography of biomolecules. Experimentals Methods in Biophysical Chemistry". (C. Nicotan, Ed.), Wiley, New York, (1973), pp. 393-414. Y. Wang, Y. Huang, B. Wang, T. Fang, J. Chen and C. Liang, J. Electroanal. Chem. 782 (2016) 76. Z. Bai, C. Zhou, H. Xu, G. Wang, H. Pang and H. Ma, Sens. Actuators B 243 (2017) 361. S.P.Kounaves, Voltammetric techniques, (Ch. 37), (2001), from: http://www. Yahoo.com/science,chemistry,electrochemistry, ch.37. htm. p. 709-725, yahoo.inc., Accessed: Sept., 15, 2003. Q. Qin, X. Bai, and Z. Hua, J. Electroanal. Chem. 782 (2016) 50. 74. Q. Zhu, J. Bao, D. Huo, M. Yang, C. Hou, H.H. Willard, L.L. Merritt and J.A. Dean, "Instrumental Methods of Analysis". 5th ed., D. Van Nostrand Company, New York, (1974), pp. 633, 637-638, 642-643, 655-656.
There are 1 citations in total.

Details

Primary Language English
Subjects Engineering
Journal Section Articles
Authors

Eman A.m. Aljawadı

Haitham A.a. Al-wahab

Publication Date December 4, 2018
Published in Issue Year 2018Issue: 4

Cite

APA Aljawadı, E. A., & Al-wahab, H. A. (2018). Clinical Applications of Uric Acid via Chemical Method using Polarography Technique Comparing with Spectrophotometric Methods. The Eurasia Proceedings of Science Technology Engineering and Mathematics(4), 156-161.